Difference between revisions of "Supply"
(some info on batteries) |
|||
(5 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{DISPLAYTITLE:Supply & Power Management}} | {{DISPLAYTITLE:Supply & Power Management}} | ||
− | == | + | == Overo Series == |
+ | === V_BATT === | ||
+ | |||
+ | === V_BACKUP_BATT === | ||
+ | |||
+ | |||
+ | === SYS_EN === | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | === Powering Gumstix Overo series from batteries === | ||
+ | |||
+ | |||
+ | == Verdex Pro, Connex and Basix Series == | ||
+ | |||
+ | |||
+ | === V_BATT === | ||
Line 17: | Line 34: | ||
− | This net powers the gumstix | + | This net powers the gumstix basix, connex and verdex pro motherboards and all related expansion boards. '''V_BATT''' is located on all modular connectors. |
− | + | === V_BACKUP_BATT === | |
− | + | ||
− | + | ||
− | == V_BACKUP_BATT == | + | |
− | + | ||
− | + | ||
Line 54: | Line 66: | ||
− | + | === SYS_EN === | |
− | + | ||
− | + | ||
− | == SYS_EN == | + | |
− | + | ||
− | + | ||
Line 69: | Line 76: | ||
+ | === Powering Gumstix Verdex Pro from batteries === | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
three or four rechargeable NiMH AA cells in a battery holder work OK. | three or four rechargeable NiMH AA cells in a battery holder work OK. | ||
Line 95: | Line 89: | ||
Related pages on the gumstix website: | Related pages on the gumstix website: | ||
− | + | https://pubs.gumstix.com/documents/Powering_a_Gumstix.pdf | |
<br> | <br> | ||
Line 114: | Line 108: | ||
. | . | ||
[[Category:Literature]] | [[Category:Literature]] | ||
+ | [[Category:How_to_-_batteries]] |
Latest revision as of 12:16, 17 March 2014
Contents
Overo Series
V_BATT
V_BACKUP_BATT
SYS_EN
Powering Gumstix Overo series from batteries
Verdex Pro, Connex and Basix Series
V_BATT
V_BATT |
GND |
- Supply voltage: 3.6V - 5.0V (max. 6.0V)
This net powers the gumstix basix, connex and verdex pro motherboards and all related expansion boards. V_BATT is located on all modular connectors.
V_BACKUP_BATT
V_BACKUP_BATT |
GND |
- Supply voltage: 3.0V
This net connects to the pin 'VBACKUP' of the power management chip TPS65022.
It exists to source power from an off-board backup battery. V_BACKUP_BATT is located on the 24-pin connector.
If your application needs a backup battery, connect a 3V Li-Ion cell directly to V_BACKUP_BATT and GND and remove R9 (0 Ohm resistor to ground).
Use a boost converter (ex. TPS61070) if you use a single NiMH battery
In systems where no backup battery is used, this net is connected to GROUND.
On the verdex, this is done with R9 (0 Ohm resistor), which is populated by default on our website-sale boards.
SYS_EN
SYS_EN |
Powering Gumstix Verdex Pro from batteries
three or four rechargeable NiMH AA cells in a battery holder work OK.
Lithium Ion batteries work well. for example VARTA 56491201012.
Related pages on the gumstix website:
https://pubs.gumstix.com/documents/Powering_a_Gumstix.pdf
Related pages on the old wiki:
http://docwiki.gumstix.org/index.php/Gumstix_motherboard_I/O#Batteries_and_power
http://docwiki.gumstix.org/index.php/Batteries
.